Installation Instructions
CKTES
TM
PETK-10 & PETK-11
Connection Kit
To be used with *Thermon Europe Series Cables
This equipment is tested and approved for hazardous areas zone 1 and zone 2, as well as safe areas and is compliant with the
following standards: EN/IEC 60079-0 (2009), EN/IEC 60079-7 (2007), EN/IEC 60079-30-1 (2007), EN/IEC 60079-31 (2009).
Ex eb IIC T2 to T6
Ex tb IIIC T260°C to T85°C IP66
SIRA 10ATEX3368X IECEx SIR10.0195X
1725
English
Français
Deutsch
Nederlands
Russian
CKTES-1 ART.NO. 420.000.101
CKTES-2 ART.NO. 420.000.102
PETK-10 ART.NO. 422.301.631
PETK-11 ART.NO. 422.301.632
Form TEP0107U-0512 © Thermon Manufacturing Co. Information subject to change.
*Thermon Europe Series Cables are in these installation guidelines denominated as TESH.
Page view 0
1 2 3 4 5 6 7 8 9

Summary of Contents

Page 1 - PETK-10 & PETK-11

Installation InstructionsCKTESTMPETK-10 & PETK-11Connection KitTo be used with *Thermon Europe Series Cables This equipment is tested and app

Page 2

Connection kit CKTES (Connection Kit Thermon Series Cable) is designed to connect a cold lead cable to a series constant watt heating cable or to repa

Page 3

Kit Contents 2Tools Required 16423589107Form TEP0107U-0512 © Thermon Manufacturing Co. Information subject to change.CKT

Page 4 - CL Not required

Details Of Cold Lead And Lug Sizes 3Form TEP0107U-0512 © Thermon Manufacturing Co. Information subject to change.In-Line Connectio

Page 5

Step 1First determine the correct circuit length, then slide the screw cap and the rubber grommet over the heating cable and cold lead cable (in case

Page 6

Step 5 Insert the bare conductor of both the Cold Lead/Heating Cable and Heating Cable into the crimp connector and ensure complete overlap of conduct

Page 7

Step 8Mount the CKTES/PETK on a at surface, with expansion loop of 150 mm in the cables. Heating Cable/Cold Leads and joint secured in place using b

Page 8 - Description

Installation Instructions for Power Termination 7DescriptionPower and End Termination Kit PETK for Thermon TESH series constant watt heatin

Page 9 - WWW.THERMON.COM

Step 3Cut and remove (10 mm) primary insulation jacket to reveal the bare conductor.Step 4Slide green/yellow ground sleeve over twisted braid. Crimp c