Tools Required
1
Applications
ET-7C
Installation Instructions
2 2 Tape Strips
3 1 RTV Tube
Item Qty Description
1 1 End Cap
Kit Contents:
The ET-7C Kit is used for end circuit termination of FP-BN con-
stant watt heating cable.
Due to the risk of electrical shock, arcing and re caused by product
damage or improper usage, installation or maintenance, a ground-fault
protection device is required.
Installation must comply with Thermon requirements and be installed
in accordance with the NEC, CEC, or any other applicable national
and local codes.
Component approvals and performance ratings are based on the use
of Thermon specied parts only.
Keep ends of heating cable and kit components dry before and during
installation.
Warnings
2
3
End Termination Kit
IP66 NEMA/Type 4X
Ordinary & Hazardous Locations
Listed Heat Tracing Cable System 137M
Certications vary by cable type. See product
specication sheets for additional information.
Certications/Approvals
4
4 1 Lug
IECEx
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Installation Instructions

Tools Required 1Applications ET-7CInstallation Instructions2 2 Tape Strips 3 1 RTV TubeItem Qty Description1 1 End Cap Kit Contents:The ET-7C

Page 2

Installation Instructions for FP-BN Cut and remove primary insulation jacket.Cut and remove heating element and berglass over-lay. Push any remainin

Page 3

3 5. 6. 7.Stagger cut one of the bus wires. 8.Tape bus wires individually and then together. Continue taping to cover overjacket.Apply a liberal amoun

Page 4 - Thermon Manufacturing Company

Cable Take-off for FP-BN 4Part No. 50070-1106Thermon Manufacturing Company100 Thermon Drive • P.O. Box 609 • San Marcos, Tex